Main Menu

PA0052 General Purpose Parameter Program


Schottkies, Roman pots, etc. (2)

Program: PA0052
<< Bob's list of dropped encl's Topic Collimators and lambertsons >>
Shottky plates: Injection into the Tevatron can take place      
                with the vertical plates in, but the hoorizontal
                plates must be out.  The vertical plates are in 
                at 467 for the top and -674 for the bottom.     
                Hor out positions are 1023 and 670.             
E0 Roman pots: ROMAN POTS ARE NO LONGER INSTALLED AT E-ZERO. McClure 5/24/2000
               are out at 24mm.  To remove the pots turn        
               T:E0PERM off the way you would turn off anything 
               from a parameter page.  The far right field      
               should be ER (Enable Ready) rather than the ...  
               for a normal parameter.  If status is not ready, 
               the Colliding Beams Tclk evt has not been issued.
               Page T108 <2> has T:E0PERM.  Page T108 <2> has   
               pot positions. 7/17/88  
                                          

Level 3 Topics:
SCHOTTKIES B0 POT label
B0 POT limit
B0 pot rboot
B0 Pneumatic
B0 Roman pot B0 POT alarm

Level 2 Topics:
Overview Cryogenics stuff
New Features MNTN RANGE/Frame Grabbers
*---->Collider Memo Pad<----* pbar clock events/ P60/DTOA/6
*-diagnostics & RF for shots-* Bunch Spreaders (MR)
SBD - Sampled Bunch Display Switchyard stuff
mults and bumps Tevatron Bunch Spreader
Display Options Pseudo-fixed target inj.
Plot Package Interfaces Transfers between machines
CATV channels
8 GeV Kickers MR RF OFF control
Mountain Ranges Bunch Length Monitors
Notes Expressions
Bob's list of dropped encl's Notify Channel modes
Schottkies, Roman pots, etc. Bugs
Collimators and lambertsons Suggestions


Page(s):
B(Booster) 2 , 3 , 5 , 6 , 8 , 9 , 11 , 12 , 18 , 19 , 27 , 28 , 43 , 56 , 69 , 71 , 99 , 109 , 111
C(Collider) 9 , 14 , 16 , 18 , 30 , 34 , 57 , 64 , 65 , 72 , 73 , 82 , 94
D(Diagnostic/Utility) 24 , 26 , 96 , 97 , 106
E(Experimental) 3 , 4 , 5 , 6 , 7 , 15 , 22 , 23 , 25 , 30 , 35 , 38 , 52 , 53 , 54 , 57 , 58 , 61 , 62 , 68 , 69
F(Refrigerator) 4 , 9 , 14 , 37 , 60 , 61 , 72 , 73 , 81
H(Hardware Diagnostic) 34 , 53 , 55
I(Main Injector) 4 , 5 , 8 , 10 , 18 , 19 , 21 , 26 , 27 , 34 , 58 , 59 , 63 , 64 , 65 , 66 , 81 , 133
L(Linac/Preacc) 2 , 3 , 4 , 5 , 6 , 7 , 8 , 12 , 14 , 26 , 29 , 30 , 38 , 41 , 44 , 45 , 46 , 48 , 49 , 66 , 68
M(Main Ring) 4 , 22 , 65
N(New Muon Lab) 2 , 3 , 4
P(P-Bar) 8 , 12 , 36 , 38 , 57 , 60 , 66 , 71 , 75 , 79 , 100 , 122 , 123 , 200 , 202
R(Recycler) 4 , 5 , 20 , 34 , 51 , 59 , 63 , 66 , 117 , 118 , 119
S(Switchyard) 3 , 4 , 15 , 16 , 17 , 18 , 21 , 41
T(Tevatron) 4 , 5 , 9 , 13 , 15 , 23 , 30 , 43 , 53 , 55 , 56 , 68 , 72 , 73 , 74 , 75 , 81 , 88 , 90 , 111 , 118 , 119 , 120
W(Work in Progress) 70 , 95 , 97 , 100

Callee(s): Data Pool Manager Peek SA (SA0020) , TO PLOT TOROID CURRENT ON STORAGE SCOPE (SA0021) , Electron Cooling losses plot (SA1022) , Linac Toroid and Losses Plot (SA1046) , This is an interpretive graphical display (Lex SA). (SA1082) , Switchyard SWIC Display (SA1086)