Main Menu

PA0052 General Purpose Parameter Program


Expressions (2)

Program: PA0052
<< Bunch Length Monitors Topic Notify Channel modes >>
The parameter page also supports algebraic expressions of ACNET devices.
To enter an expression, the first character typed in should be a pound
sign (#).  Then type in your expression.  Either the reading or setting
property can be specified for a device.  If the second character in the
name is a colon (:), the reading property will be used.  If the second
character is an underscore (_), the setting property will be used.

The operators supported are:

+ -> addition
- -> subtraction
* -> multiplication
/ -> division
^ -> exponentiation
% -> integer modulus


EXAMPLE:

#A:IBEAM/L:D7TOR   <--- note USE of COLON, not semicolon.

The use of parentheses in expressions is fully supported.

The following math functions are also supported:

sqrt	-> square root
ln	-> natural log
log	-> base 10 log
sin	-> sine
cos	-> cosine
tan	-> tangent


Level 2 Topics:
Overview Cryogenics stuff
New Features MNTN RANGE/Frame Grabbers
*---->Collider Memo Pad<----* pbar clock events/ P60/DTOA/6
*-diagnostics & RF for shots-* Bunch Spreaders (MR)
SBD - Sampled Bunch Display Switchyard stuff
mults and bumps Tevatron Bunch Spreader
Display Options Pseudo-fixed target inj.
Plot Package Interfaces Transfers between machines
CATV channels
8 GeV Kickers MR RF OFF control
Mountain Ranges Bunch Length Monitors
Notes Expressions
Bob's list of dropped encl's Notify Channel modes
Schottkies, Roman pots, etc. Bugs
Collimators and lambertsons Suggestions


Page(s):
B(Booster) 2 , 3 , 5 , 6 , 8 , 9 , 11 , 12 , 18 , 19 , 27 , 28 , 43 , 56 , 69 , 71 , 99 , 109 , 111
C(Collider) 9 , 14 , 16 , 18 , 30 , 34 , 57 , 64 , 65 , 72 , 73 , 82 , 94
D(Diagnostic/Utility) 24 , 26 , 96 , 97 , 106
E(Experimental) 3 , 4 , 5 , 6 , 7 , 15 , 22 , 23 , 25 , 30 , 35 , 38 , 52 , 53 , 54 , 57 , 58 , 61 , 62 , 68 , 69
F(Refrigerator) 4 , 9 , 14 , 37 , 60 , 61 , 72 , 73 , 81
H(Hardware Diagnostic) 34 , 53 , 55
I(Main Injector) 4 , 5 , 8 , 10 , 18 , 19 , 21 , 26 , 27 , 34 , 58 , 59 , 63 , 64 , 65 , 66 , 81 , 133
L(Linac/Preacc) 2 , 3 , 4 , 5 , 6 , 7 , 8 , 12 , 14 , 26 , 29 , 30 , 38 , 41 , 44 , 45 , 46 , 48 , 49 , 66 , 68
M(Main Ring) 4 , 22 , 65
N(New Muon Lab) 2 , 3 , 4
P(P-Bar) 8 , 12 , 36 , 38 , 57 , 60 , 66 , 71 , 75 , 79 , 100 , 122 , 123 , 200 , 202
R(Recycler) 4 , 5 , 20 , 34 , 51 , 59 , 63 , 66 , 117 , 118 , 119
S(Switchyard) 3 , 4 , 15 , 16 , 17 , 18 , 21 , 41
T(Tevatron) 4 , 5 , 9 , 13 , 15 , 23 , 30 , 43 , 53 , 55 , 56 , 68 , 72 , 73 , 74 , 75 , 81 , 88 , 90 , 111 , 118 , 119 , 120
W(Work in Progress) 70 , 95 , 97 , 100

Callee(s): Data Pool Manager Peek SA (SA0020) , TO PLOT TOROID CURRENT ON STORAGE SCOPE (SA0021) , Electron Cooling losses plot (SA1022) , Linac Toroid and Losses Plot (SA1046) , This is an interpretive graphical display (Lex SA). (SA1082) , Switchyard SWIC Display (SA1086)