Main Menu

PA0052 General Purpose Parameter Program


SBD - Sampled Bunch Display (2)

Program: PA0052
<< *-diagnostics & RF for shots-* Topic mults and bumps >>
  As of this date (6-20-96), the fixed target SBD is running.   
The collider SBD has been turned off, so those Acnet devices    
will be inactive.  Fixed target SBD returns bunch intensity and 
optionally, RMS sigma & width information for each bucket in the
Tevatron.  The system is located at F0.  A LeCroy 2 GSample/sec 
scope digitizes a beam signal from the resistive wall current   
monitor.  A Macintosh with an Acnet interface processes the     
data.  Graphical display of intensity data is sent to TV channel
22.  C30 pages 1-4 has SBD Acnet devices.  The subtopics below  
are obsolete.     Click here for more information.   
                                    - Ed Barsotti, Jun 20 1996. 
----------------------------------------------------------------
For more HELP see subtopics below or Instrum. rookie book.      

Level 3 Topics:
SBD working? Tev mode SDA/Datalog MR 1st turn
Debugging FastTev mode Acnet dev's Old SBD info
Seq problem? Injections Coalesced
Rebooting TV Displays Uncoalesced 2A,2B study
System info Param pages Sav profile Bunch times

Level 2 Topics:
Overview Cryogenics stuff
New Features MNTN RANGE/Frame Grabbers
*---->Collider Memo Pad<----* pbar clock events/ P60/DTOA/6
*-diagnostics & RF for shots-* Bunch Spreaders (MR)
SBD - Sampled Bunch Display Switchyard stuff
mults and bumps Tevatron Bunch Spreader
Display Options Pseudo-fixed target inj.
Plot Package Interfaces Transfers between machines
CATV channels
8 GeV Kickers MR RF OFF control
Mountain Ranges Bunch Length Monitors
Notes Expressions
Bob's list of dropped encl's Notify Channel modes
Schottkies, Roman pots, etc. Bugs
Collimators and lambertsons Suggestions


Page(s):
B(Booster) 2 , 3 , 5 , 6 , 8 , 9 , 11 , 12 , 18 , 19 , 27 , 28 , 43 , 56 , 69 , 71 , 99 , 109 , 111
C(Collider) 9 , 14 , 16 , 18 , 30 , 34 , 57 , 64 , 65 , 72 , 73 , 82 , 94
D(Diagnostic/Utility) 24 , 26 , 96 , 97 , 106
E(Experimental) 3 , 4 , 5 , 6 , 7 , 15 , 22 , 23 , 25 , 30 , 35 , 38 , 52 , 53 , 54 , 57 , 58 , 61 , 62 , 68 , 69
F(Refrigerator) 4 , 9 , 14 , 37 , 60 , 61 , 72 , 73 , 81
H(Hardware Diagnostic) 34 , 53 , 55
I(Main Injector) 4 , 5 , 8 , 10 , 18 , 19 , 21 , 26 , 27 , 34 , 58 , 59 , 63 , 64 , 65 , 66 , 81 , 133
L(Linac/Preacc) 2 , 3 , 4 , 5 , 6 , 7 , 8 , 12 , 14 , 26 , 29 , 30 , 38 , 41 , 44 , 45 , 46 , 48 , 49 , 66 , 68
M(Main Ring) 4 , 22 , 65
N(New Muon Lab) 2 , 3 , 4
P(P-Bar) 8 , 12 , 36 , 38 , 57 , 60 , 66 , 71 , 75 , 79 , 100 , 122 , 123 , 200 , 202
R(Recycler) 4 , 5 , 20 , 34 , 51 , 59 , 63 , 66 , 117 , 118 , 119
S(Switchyard) 3 , 4 , 15 , 16 , 17 , 18 , 21 , 41
T(Tevatron) 4 , 5 , 9 , 13 , 15 , 23 , 30 , 43 , 53 , 55 , 56 , 68 , 72 , 73 , 74 , 75 , 81 , 88 , 90 , 111 , 118 , 119 , 120
W(Work in Progress) 70 , 95 , 97 , 100

Callee(s): Data Pool Manager Peek SA (SA0020) , TO PLOT TOROID CURRENT ON STORAGE SCOPE (SA0021) , Electron Cooling losses plot (SA1022) , Linac Toroid and Losses Plot (SA1046) , This is an interpretive graphical display (Lex SA). (SA1082) , Switchyard SWIC Display (SA1086)