module _c28903;
title 'C289 Qualifier Kluge CAMAC function decoder
19-May-1999
Checksum: 3E9F
Fuse #: 0495'
c28903 device 'F173';
"Pin definitions
F16,F8,F4,F2,F1 pin 1,2,3,4,5; "Function codes
A8,A4,A2,A1 pin 6,7,8,10; "Subaddress
N,Z,S1,S2 pin 9,14,11,13; "Control lines
DF6,DF1 pin 15,16; "Decoded functions
CLR,PUC pin 17,22; "Clear, Power up clear
QX pin 18; "Q and X response
GND,VCC pin 12,24; "Power and ground
"Macros
func = [!F16,!F8,!F4,!F2,!F1];
addr = [!A8,!A4,!A2,!A1];
equations
!QX = !N & (func==1) & (addr==0) & PUC "F(1) A(0)
# !N & (func==6) & (addr==0) & PUC "F(6) A(0)
# !N & (func==7) & (addr==0) & PUC "F(7) A(0)
# !N & (func==9) & (addr==0) & PUC; "F(9) A(0)
!DF6 = !N & (func==6) & (addr==0) & PUC; "F(6) A(0)
!DF1 = !N & (func==1) & (addr==0) & PUC; "F(1) A(0)
!CLR = !N & (func==9) & (addr==0) & S1 & PUC "F(9) A(0) S1
# !Z & !S2
# !PUC;
"DESCRIPTION: This PAL provides the NAF decoding for the CAMAC
" 289 module. A F(7)A(0) code for a
" no-op read is included in the QX term.
end _c28903