dio_node_default_alarm_list_c

	status.i4.v = dio_node_default_alarm_list_c(node.i4.v, alarm_list.i4.r)

	This routine returns the default alarm list number for a given node.

	node		front end node (constants are in 'nodedefs')
	alarm_list	returned default alarm list number

	This function returns status values as follows:

	OK			success
	DIO_BADARG		invalid node value passed
	DIO_MEMFAIL		memory allocation failure
	DIO_NO_SUCH		node is not mapped to a default alarm list
	SQL_xxx			error reading default alarm list information

	This function requires the following include files:

	nodedefs_h, diolib_h, acnet_errors_h

	Related functions:

	dio_node_default_alarm_list_list_c, dio_alarm_list_id_c,
	dio_get_db_alarm(_c), dio_get_alarm(_c), dio_get_alrm_lst,
	dio_extract_alarm_info_c, dio_analog_alarm_text_c,
	dio_digital_alarm_text(_c), dio_desired_alarm_limit_type,
	dio_set_alarm_flags_c

	C/C++ usage:

	int	status;
	int	node = TEVA;
	int	alarm_list;

	status = dio_node_default_alarm_list_c(node,&alarm_list);