swdef DEPRECATED

	CALL SWDEF( SWNUM, ULROW, ULCOL, LRROW, LRCOL, FLAGS )

	This routine will define switch number SWNUM on the touch panel. Any
	previous definition of this switch is deleted.  Valid switch numbers
	are from 0 to 31.  All the arguments are INTEGER*2.  ULROW and ULCOL
	specify the row and column of the upper left corner  of  the  switch
	rectangle.  LRROW and LRCOL specify the row and column of the  lower
	right corner of the switch rectangle.  Switch definition  rectangles
	should not overlap.  Unpredictable operation will result if they do.
	FLAGS specify the switch attributes as follows:

			MEANING			MEANING
	BIT	 |	IF = 0			IF = 1
	---------+--------------------------------------------------------
	0 (LSB)	 |	OFF		      ON  (This bit must be 0 for
		 |				   momentary switches)
	1	 |	MOMENTARY	      LATCHING
	         |
	2	 |	AUTO COLOR	      AUTO COLOR
		 |	CHANGE DISABLED	      CHANGE ENABLED

	If auto color change is  enabled  the  Application  Program  Manager
	will rewrite the switch text in  white  on  black  when  the  switch
	changes to the off state and in black on white when  it  changes  to
	the on state.