frig_cancel_get_c (ul_friglib)

	status.i4.v = frig_cancel_get_c(house.ch.d, name.ch.d,
					[,num_entries.i4.v] [,ftd.i2.v])

	This routine cancels existing repetitive readings of refrigerator data.

	house		house name (HOUSE_NAME_LEN characters),
	name		name of data being read ("xxxx_nnn")
			(Name format descriptions can be found under
			 the help topic frig_name_syntax.)
	[num_entries]	number of entries (default is 1)
	[ftd]		frequency time descriptor
			(FTD_ONESHOT -> one shot (default),
			 FTD_DEFAULT -> use database default FTD,
			 FTD_1HZ -> 1 Hz request,
			 FTD_EVENT_MASK OR'ed with TCLK event value -> read
			 on TCLK event (event constants are in tclk_events))

	This function returns ACNET status values as follows:

	DIO_OK			success
	DIO_CANFAIL		entry not found

	This function requires the following include files:

	ul_friglib_h:friguti_h, diolib_h, acnet_errors_h, tclk_events_h

	Related functions:

	frig_get_c, frig_get_status_c, frig_get_value_c, frig_cancel_list_c

	C usage:

	static const char	house[HOUSE_NAME_LEN+1] = "A1";
	static const char	name[] = "FSM_0";
	short	ftd = FTD_ONESHOT;
	int	status;
	int	num_entries = 1;

	status = frig_cancel_get_c(house,name,num_entries,ftd);