CAMAC C004 NMOA

Description

The NMOA module is used to qualify the generation of the TCLK $4E, $5E and $A6 requests. The input signals must be valid for greater than one millisecond before the event request is passed on. This filter supresses the request for events caused by noise on the input signal.

The NMOA module also 'OR's the two sources for an $80 request: The TLG and a CAMAC 377 channel.

The C004 module has a diagnostic TCLK decoder with associated LEDs and front panel LEMO outputs for events $4E and $5E.

CAMAC Function codes

CAMAC Function Codes
F(6)A(0)Read module number 004
F(7)A(0)Dummy read, no data are returned
F(9)A(0)Clear module (Doesn't really do anything)

I/O Assignments

1LGND 1RTCLK IN
2LGND 2R 
3LGND 3RTCLK OUT
4LGND 4R 
5LGND 5R$4E REQUEST IN (+24V)
6LGND 6R 
7LGND 7R$80 REQUEST (C377)
8LGND 8R 
9LGND 9R$5E REQUEST IN
10LGND10R 
11LGND11R$80 REQUEST (TLG)
12LGND12R$A6 REQUEST IN (NUMI Beam Permit)
13LGND13RDCE OUT
14LGND14R$4E REQUEST OUT
15LGND15R$80 REQUEST OUT
16LGND16R$5E REQUEST OUT
17LGND17R$A6 REQUEST OUT
18LGND18R 