dio_set_alarm_flags_list_c

	status.i4.v = dio_set_alarm_flags_list_c(device_indices.i4a.r,
						 alarm_type.i4.v, display.i4.v,
						 logging.i4.v, errors.i2a.r,
						 num_devices.i4.v)

	This routine will set the alarm display and logging flags in the
	database for a list of devices.

	device_indices	device index or array of device indices
	alarm_type	type of alarm
			(DIO_ANALOG -> analog alarm,
			 DIO_DIGITAL -> digital alarm)
	display		alarm display value to set
			(TRUE -> enable alarm display,
			 FALSE -> disable alarm display,
			 DIO_DONT_CARE -> leave flag in its present state)
	logging		alarm logging value to set
			(TRUE -> enable alarm logging,
			 FALSE -> disable alarm logging,
			 DIO_DONT_CARE -> leave flag in its present state)
	errors		returned ACNET status value or array of status values
	num_devices	number of devices

	This function returns ACNET status values as follows:

	OK			success
	DIO_MEMFAIL		memory allocation failure
	negative value		other ACNET format error

	This function requires the following include files:

	cnsparam_h, diolib_h, acnet_errors_h

	Related functions:

	dio_set_alarm_flags_c, dio_get_db_alarm(_c), dio_get_alarm(_c),
	dio_get_alrm_lst, dio_extract_alarm_info_c, dio_alarm_list_id_c,
	error_in_list(_c)

	C/C++ usage:

	short	errors[NUM_DEVICES];
	int	status;
	static const int	device_indices[NUM_DEVICES] = {14430, 14431};
	int	alarm_type = DIO_DIGITAL;
	int	display = TRUE;
	int	logging = FALSE;
	int	num_devices = NUM_DEVICES;

	status = dio_set_alarm_flags_list_c(device_indices,alarm_type,display,
					    logging,errors,num_devices);