crg_separator_angle_to_volts (ul_crg)

	status.i4.v = crg_separator_angle_to_volts(file_number.i4.v,
						   energy.r4.v, angles.r4a.r,
						   volts.r4a.r, plane.i4.v)

	Convert an array of separator angles to an array of volts.

	file_number	which CRG file number to take the calcuation
			constants from
	energy		the energy for these angles
	angles		An array of separator angles in urad. These are
			assumed to be in the order displayed in the CRG
			application. This should be preallocated by the user.
	volts		An array of the voltage results returned.  These are
			put in the order of the display in the CRG application.
			This array should be preallocated by the user.

	This function returns ACNET status values as follows:

	SQL_OK			success
	SQL_xxx			error in reading database

	This function requires the following include files:

	ul_crg_h:crg_h, acnet_errors_h

	Related functions:

	crg_active_file, cnv_time_energy, crg_param_read, crg_tecar_read,
	crg_read_tuner, crg_read_b2min_slope, crg_tecar_c_to_ftn